upgrade rom-monitor slot 6 sp file tftp://192.168.1.2/c6ksup720-rm2.srec.8-5-4.srec //升級CatOS ROMMONide

upgrade rom-monitor slot 6 rp file tftp://192.168.1.2/c6msfc3-rm2.srec.122-17r.SX7 //升級IOS ROMMON Softwaremd5

upgrade rom-monitor slot 5 sp file tftp://192.168.1.2/c6ksup720-rm2.srec.8-5-4.srecflash

upgrade rom-monitor slot 5 rp file tftp://192.168.1.2/c6msfc3-rm2.srec.122-17r.SX7it

copy tftp://192.168.1.2/s72033-boot-mz.122-33.SXI3.bin bootflash:class

copy tftp://192.168.1.2/s72033-boot-mz.122-33.SXI3.bin slavebootflash: //上傳bootloadermodule

copy tftp://192.168.1.2/s72033-adventerprisek9_wan-vz.122-33.SXI3.bin sup-bootflash:ftp

copy tftp://192.168.1.2/s72033-adventerprisek9_wan-vz.122-33.SXI3.bin slavesup-bootflash://上傳bootfile

copy tftp://192.168.1.2/c6500-fpd-pkg.122-33.SXI3.pkg sup-bootflash:db

copy tftp://192.168.1.2/c6500-fpd-pkg.122-33.SXI3.pkg slavesup-bootflash: //上傳fpd

verify /md5 bootflash:s72033-boot-mz.122-33.SXI3.bin 27457108988653aa8ae012b28a60abce

verify /md5 slavebootflash:s72033-boot-mz.122-33.SXI3.bin 27457108988653aa8ae012b28a60abce //驗證bootloader

verify /md5 sup-bootflash:s72033-adventerprisek9_wan-vz.122-33.SXI3.bin 9e31abc3bbaee41f2086ce3b48c8f1af

verify /md5 slavesup-bootflash:s72033-adventerprisek9_wan-vz.122-33.SXI3.bin 9e31abc3bbaee41f2086ce3b48c8f1af //驗證boot

verify /md5 sup-bootflash:c6500-fpd-pkg.122-33.SXI3.pkg 2f198062eac5b2f667efd293b236a379

verify /md5 slavesup-bootflash:c6500-fpd-pkg.122-33.SXI3.pkg 2f198062eac5b2f667efd293b236a379 //驗證fpd

boot bootldr bootflash:s72033-boot-mz.122-33.SXI3.bin

boot system flash sup-bootflash:s72033-adventerprisek9_wan-vz.122-33.SXI3.bin

hw-module module 6 reset //重啓Standby引擎slot 6

redundancy force-switchover //等待slot 6啓動完成爲STANDBY COLD後強制手動切換引擎

兩塊引擎的依次升級切換重啓,最大限度的下降網絡中斷時間。若是沒法到STANDBY COLD的話,那就老老實實的reload吧。