思科的交換機提及堆疊,主要包括數據堆疊和電源堆疊,今天咱們簡單看一下兩種堆疊。ide
1、數據堆疊spa
一、實際堆疊線纜以下:blog
二、堆疊鏈接圖示:圖片
三、實際鏈接圖示:get
四、查看堆疊狀態:it
SDYC-3850-STACK#show switch
Switch/Stack Mac Address : 6cdd.30ab.1a00 - Local Mac Address
Mac persistency wait time: Indefinite
H/W Current
Switch# Role Mac Address Priority Version State
-------------------------------------------------------------------------------------
*1 Active 6cdd.30ab.1a00 1 V07 Ready
2 Standby 6cdd.30ab.4380 1 V07 Ready
走到這裏數據堆疊基本已經完成了。io
2、電源堆疊class
一、堆疊線纜sed
在這裏忘記拍實物圖片了,只能用這個圖片了。im
二、鏈接圖示:
三、實際鏈接圖示:
四、查看電源堆疊狀態:
SDYC-3850-STACK#show stack-power detail
Power Stack Stack Stack Total Rsvd Alloc Unused Num Num
Name Mode Topolgy Pwr(W) Pwr(W) Pwr(W) Pwr(W) SW PS
-------------------- ------ ------- ------ ------ ------ ------ --- ---
Powerstack-1 SP-PS Ring 700 140 560 0 2 2
Power stack name: Powerstack-1
Stack mode: Power sharing
Stack topology: Ring
Switch 1:
Power budget: 280
Power allocated: 280
Low port priority value: 21
High port priority value: 12
Switch priority value: 3
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: Switch 2 - 6cdd.30ab.4380
Neighbor on port 2: Switch 2 - 6cdd.30ab.4380
Switch 2:
Power budget: 280
Power allocated: 280
Low port priority value: 22
High port priority value: 13
Switch priority value: 4
Port 1 status: Connected
Port 2 status: Connected
Neighbor on port 1: Switch 1 - 6cdd.30ab.1a00
Neighbor on port 2: Switch 1 - 6cdd.30ab.1a00
電源堆疊的好處:
以上圖爲例,當一臺3850的電源徹底壞掉以後,仍然可以正常工做,這時由另一臺交換機的電源爲其供電。