若是使用802.1q封裝,要確保Trunk鏈路兩端的Native VLAN的配置相同。網絡
如圖所示ide
PC1和PC3屬於VLAN2,IP地址分別爲PC1:192.168.0.2/24,PC3:192.168.0.3/24測試
PC2和PC4屬於VLAN3,IP地址分別爲PC2:192.168.1.2/24 PC4:192.168.1.3/24spa
網絡管理員配置設備後發現屬於相同VLAN的主機沒法通訊,應如何解決?3d
SW1配置信息爲:blog
Switch1(config)#interface fastEthernet 0/1接口
Switch1(config-if)#switchport access vlan 2get
Switch1(config-if)#switchport mode access it
Switch1(config)#interface fastEthernet 0/2io
Switch1(config-if)#switchport access vlan 3
Switch1(config-if)#switchport mode access
Switch1(config)#interface fastEthernet 0/24
Switch1(config-if)#switchport mode dynamic auto
SW2配置信息爲:
interface FastEthernet0/1
switchport access vlan 2
switchport mode access
!
interface FastEthernet0/2
switchport access vlan 3
switchport mode access
Switch2(config)#interface fastEthernet 0/24
Switch2(config-if)#switchport mode dynamic auto
首先,須要須要肯定交換機之間的連通性:而後,在查看交換機的配置和端口的協商。經檢查交換機的物理鏈路正常,使用show int fastEthernet 0/24 switchport 命令查看接口模式:
Switch1#show int fastEthernet 0/24 switchport
Name: Fa0/24
Switchport: Enabled
Administrative Mode: dynamic auto //管理模式
Operational Mode: static access //工做模式
Administrative Trunking Encapsulation: dot1q //管理的Trunk的封裝模式
Operational Trunking Encapsulation: native
Negotiation of Trunking: On
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
發現SW1,SW2的F0/24的接口工做模式爲access模式,致使網絡不通。
分別更爲SW和SW2交換機的接口模式,使其成爲Trunk模式,配置以下:
Switch1(config)#int fa0/24
Switch1(config-if)#sw mo trunk
Switch1(config)#int fa0/24
Switch1(config-if)#sw mo trunk
更改完成後,經測試,PC1和PC3,PC2和PC4可以正常通訊。
當兩臺Cisco Catalyst 交換機鏈接時,鏈接的端口會進行協商,因爲端口配置不一樣會有不一樣的協商結果。